Access control
Clear APB list on KC80 controllers (by credential type)
Access
Member of the organization with this permission:
access-control:operate
An API key with scopes also needs the permission among its scopes.
POST
Creates SYSTEM controller operations (CBLADALL) for each active Koole KC80 whose access method types include NFC or QR_CODE, then pings the connector via operation-sync MQTT to claim and execute them immediately (no full access-control sync).
ApiKeyAuthheader
x-api-key<token>API key for authentication
organizationId*stringThe ID or slug of the organization
application/json- body
accessMethodType*stringValue in
"NFC""QR_CODE"OK
application/json- response
curl -X POST 'https://api.tillor.eu/orgs//access-controllers/clear-apb-list' \ -H 'Content-Type: application/json' \ -d '{ "accessMethodType": "NFC"}'Example Response
nullClose AccessPoint POST
Closes an access point by ID (optional closeConfig required for CONNECTOR)
Push pending access-control data from connector POST
Publishes MQTT so the connector uploads queued access-log entries (e.g. LPR), applies connector controller operations, and polls connected access hardware for pending log lines.